AL ATEX DUST – explosion-proof centrifugal fans for combustible dust atmospheres ≤11200 m³/h

AL ATEX DUST – explosion-proof centrifugal fans

AL ATEX DUST industrial centrifugal fans with forward-curved Sirocco-type impeller blades are designed for ducted ventilation systems installed in potentially explosive combustible dust atmospheres. Suitable for ATEX Zone 21, they comply with Directive 2014/34/EU and carry the marking II 2D Ex h IIIB T135°C Db. The manufacturer's declared series airflow range is 1500–11200 m³/h, with pressures up to 1900 Pa.

Main features

  • ATEX construction for combustible dust atmospheres, Zone 21, equipment category II 2D.
  • Fan ATEX marking: II 2D Ex h IIIB T135°C Db.
  • Type Examination Statement IMQ 10 ATEX 017 X.
  • Applicable standards EN 14986:2017, EN 1127-1, EN ISO 80079-36 and EN ISO 80079-37.
  • Designed to convey clean air in industrial ducted installations requiring high pressure.
  • Volute casing manufactured from steel sheet with protective epoxy-polyester powder coating.
  • Single-inlet Sirocco-type impeller with forward-curved blades.
  • Galvanised steel impellers for sizes 200–315; welded and painted steel impellers for sizes 355–450.
  • Painted steel sheet inlet cone.
  • Direct drive, arrangement 4 construction.
  • Explosion-protected single-phase or three-phase asynchronous motors for combustible dust atmospheres.
  • Motor enclosure protection IP66, insulation class F and continuous duty S1.
  • Motor dust group IIIC, protection by enclosure „tb“ according to IEC 60079-0 and IEC 60079-31.
  • PTC thermistors for motor overheating protection.
  • Speed control of three-phase motors using a suitable frequency inverter in accordance with manufacturer requirements.
  • Conveyed air temperature from -20 °C to +60 °C; from -40 °C to +60 °C on request.
  • 60 Hz versions and temperature classes T5 or T6 available on request.

The motor's IIIC „tb“ classification must not be confused with the complete fan's IIIB ATEX classification.

Fan casing orientations

Standard discharge orientation LG270°. The casing can be rotated in 45° increments. Orientations of 180° and 225° require special factory construction.

Centrifugal fan casing orientations LG and RD

Optional accessories

  • Round inlet adaptor.
  • Inlet protection guard.
  • Outlet protection guard.

Accessories are not included in the Type Examination Statement. Their suitability for the specific ATEX installation must be assessed separately.

AL ATEX DUST – technical catalogue (PDF)


Brand: DYNAIR

AL ATEX DUST – dimensions

All dimensions are in millimetres (mm); indicative weights are in kilograms (kg). Symbols correspond to the manufacturer's dimensional drawing.

SizeABCDEFGHILØMkg
AL ATX 200183176120156280703551031402181220
AL ATX 225210193141175310783451111402181232
AL ATX 250231210162193335903751202052701239
AL ATX 280257230170216365984101322052701240
AL ATX 3152882521922454051095701402053191255
AL ATX 3553212752122704451214801532453541573
AL ATX 40035830323530150513665016824537015123
AL ATX 45040633726733756015169518334043915146

Connection and mounting dimensions

SizeabcdefghØiØlØmØnn°o
AL ATX 20018013575213100168240195164235255M610
AL ATX 22520015575233100188260215189260280M610
AL ATX 25022017575253100208280235210290310M610
AL ATX 280260195100293125228320255240310340M810
AL ATX 315300215100333150248360275275335375M810
AL ATX 355340240125373100273400300302395425M812
AL ATX 400388273125425100310465350352445465M812
AL ATX 450430300150470100340510380402490520M812

Dimensional drawing

AL centrifugal fan dimension symbols

The illustration shows the dimension symbols. AL ATEX DUST values must be taken from the tables above and the manufacturer's catalogue.

Original AL ATEX DUST dimensional drawing (PDF, page 6)

AL ATEX DUST – technical information

ParameterValue
ManufacturerDYNAIR / MAICO ITALIA, Italy
SeriesAL ATEX DUST
TypeForward-curved centrifugal fan
ApplicationATEX Zone 21, combustible dust atmosphere
ATEX categoryII 2D
ATEX markingII 2D Ex h IIIB T135°C Db
Conveyed mediumClean air
Manufacturer's series airflow range1500–11200 m³/h
Highest catalogue model Qmax10770 m³/h
Series pressureUp to 1900 Pa
Conveyed air temperature-20 °C to +60 °C
Temperature on request-40 °C to +60 °C
MotorExplosion-protected asynchronous, single-phase or three-phase
Catalogue model power supply230 V / 3-phase / 50 Hz or 400 V / 3-phase / 50 Hz
Motor power0.25–9.00 kW
Motor dust group and protectionIIIC, „tb“
Enclosure protectionIP66
Insulation classF
Duty ratingS1
Thermal protectionPTC thermistors
Speed controlFrequency inverter for three-phase versions
CasingSteel with epoxy-polyester powder coating
ImpellerForward-curved blades; galvanised steel or welded and painted steel
Standard discharge orientationLG270°
ATEX Directive2014/34/EU
Type Examination StatementIMQ 10 ATEX 017 X

AL ATEX DUST – model specifications

Qmax is the maximum permissible airflow. Pt min is the minimum operating total pressure, not the fan's maximum pressure.

CodeModelPolesPower, kWCurrent, AQmax, m³/hPt min, Pa
1XA0000AL ATX 20221.102.4017001050
1XA0001AL ATX 20440.250.801550211
1XA0002AL ATX 22222.204.4027201382
1XA0003AL ATX 22440.551.501950329
1XA0004AL ATX 25223.005.502920472
1XA0005AL ATX 25440.752.002450371
1XA0006AL ATX 25660.371.251930124
1XA0007AL ATX 284 A41.503.303540*452*
1XA0008AL ATX 284 B41.102.703540*452*
1XA0009AL ATX 28660.752.702820174
1XA0010AL ATX 314 A43.006.505760*482*
1XA0011AL ATX 314 B42.205.505760*482*
1XA0012AL ATX 31661.102.704200195
1XA0013AL ATX 354 A44.008.807660425
1XA0014AL ATX 354 B43.006.506715500
1XA0015AL ATX 35661.503.805030197
1XA0016AL ATX 35880.752.60368090
1XA0017AL ATX 404 A47.5014.409300250
1XA0018AL ATX 404 B45.5011.9458501115
1XA0019AL ATX 40662.205.406290325
1XA0020AL ATX 40881.103.004720185
1XA0021AL ATX 45449.0017.50107701200
1XA0022AL ATX 45664.008.047140355
1XA0023AL ATX 45882.205.205450200

* For models 284 A/B and 314 A/B the catalogue provides common operational limit values for each model group. Each variant must be selected using its own performance characteristics.

Air performance measured according to EN ISO 5801 / AMCA 210 at an air density of 1.2 kg/m³.

AL ATEX DUST – manufacturer's technical catalogue (PDF)

AL ATEX DUST – installation instructions

AL ATEX DUST centrifugal fans are intended for industrial ducted ventilation systems installed in potentially explosive combustible dust atmospheres. Before installation, verify that the equipment's ATEX classification is suitable for the designated hazardous area.

Mounting

  • Secure the fan to a rigid supporting structure suitable for its weight and operating loads.
  • Provide access to the motor, casing and maintenance points.
  • Prevent ductwork from transmitting excessive mechanical loads to the casing.
  • Before commissioning, inspect the mounting fasteners and make sure the impeller rotates freely.

Duct system and airflow

Forward-curved centrifugal fans must operate connected to ductwork or with sufficient additional aerodynamic resistance, such as balancing dampers. System resistance must limit airflow so that the absorbed motor current does not exceed the permissible value stated on the motor rating plate.

Casing orientation

The standard discharge orientation is LG270°. The casing can be rotated in 45° increments, excluding the 180° and 225° positions which require special factory construction.

Electrical connection

  • Connect the electrical supply according to the motor rating plate and applicable ATEX requirements.
  • Ensure protective earthing and suitable protection of electrical connections.
  • Connect the PTC thermistors to a suitable motor thermal protection circuit.
  • Use frequency inverter speed control of three-phase motors only under conditions approved by the manufacturer.

Commissioning

  • Check impeller rotation direction and freedom of movement.
  • Inspect duct connections and protective components.
  • Measure the absorbed motor current and compare it with the rated value.
  • Check for abnormal vibration, noise and motor overheating.
  • Do not exceed the specified airflow and temperature limits.

Maintenance

Regularly inspect the casing, impeller, motor and protective devices. Prevent deposits of combustible dust. Before maintenance, isolate the electrical supply, protect against accidental restart and follow safety procedures applicable to explosive atmospheres.

AL ATEX DUST – manufacturer's technical catalogue (PDF)