Dust extraction fans and material handling fans convey sawdust, chips, wood or food pellets, shredded paper, plastic and leather through ducts to a cyclone or filter. The self-cleaning impeller creates high pressure and does not clog.
A conveying fan carries dust, chips and sawdust through ducts to cyclones or filters. Choose by airflow and pressure.
Choose by airflow (m³/h), pressure and duct length; for chips keep 18–20 m/s in the duct. W-T fans come with a transition to a round duct, standard housing RD0 (P0), others on order. Maximum air temperature: W-T 70 °C, IVWTP and IVWPSW 60 °C. For explosive dust use only IVWTK EX.
Accessories: SKO ducts Ø250–500 mm, 90° elbows, E600 frequency inverters. Ready-made kits with filter are in dust collection systems.
W-T series: W-T1O, W-T2O, W-T2C, W-T3O, W-T3C, W-T4O, W-T4C, W-T5O, W-T5C, W-T7C, W-T11C and W-T18C from 1950 to 14000 m³/h. IVWTP (up to 4500 m³/h) and IVWPSW (up to 10500 m³/h) for low dust concentrations. IVWTK EX (up to 20000 m³/h) for explosive dust.
Yes, IVWTK EX to ATEX: zone 21 inside the fan, zone 22 outside, temperature class T1–T3 (T4 on request), group II (IIA, IIB). An EX starter is required; speed control is not possible.
The W-T series is designed for sawdust and chips: particle concentration up to 0.1–0.2 kg/m³, air up to 70 °C. Choose the model by airflow, pressure and duct length, keeping 18–20 m/s in the duct.
For speed control we offer E600 frequency inverters 0.2–5.5 kW, sold separately. IVWTK EX fans are not designed for speed control.
The W-T fan comes with a transition to a round duct. Use SKO ducts Ø250–500 mm and 90° elbows, and seal joints with adhesive cloth tape.