Duct dampers regulate or tightly shut off air flow in ventilation systems. We offer:

  • manual volume control dampers RSK, RSKG and airtight shut-off dampers RSKH;
  • polyurethane dampers RSKS that also reduce noise;
  • dampers for HDPE ducts Ø75 and 90 mm;
  • dampers SEPG for actuators – motorised air dampers with NENUTEC actuators;
  • guillotine dampers RSKI for dust and sawdust systems;
  • back-draft dampers AVGI.

Dampers are fitted in duct branches so that each room receives the right amount of air and the system is balanced. Manual dampers are set once during commissioning, while motorised dampers can close the duct automatically when ventilation is switched off.

Read more at the bottom of the page

Ventilation dampers for ducts: how to choose

Air dampers are chosen by duct diameter, purpose (air flow control or tight shut-off) and control (manual or with an electric actuator).

Manual air flow control and shut-off dampers

  • RSK – air flow control dampers made of galvanised sheet steel for Ø100 and 125 mm ducts.
  • RSKG – manual control dampers made of galvanised sheet steel with rubber gaskets for Ø100–400 mm ducts.
  • RSKH – air flow shut-off dampers for Ø100–315 mm ducts, with sleeves and rubber gaskets, tightness class 4 according to EN 1751.
  • RSK HDPE – dampers for HDPE ducts Ø75 and 90 mm. RSKG75 (Ø75 mm with rubber gasket) is always in stock.
  • RSKS – polyurethane dampers for Ø80–315 mm ducts that control air flow and reduce noise (DIN 4102-1, class B2). Installed in the end branch of the duct before the diffuser or grille; the air flow is set by increasing the number of open holes.

Dampers with an electric actuator (automatic air flow dampers)

  • SEPG – galvanised sheet steel dampers with rubber gaskets for Ø100–315 mm ducts, designed for an electric actuator.
  • NENUTEC Standard 2/3 – electric damper actuators 2–40 Nm: NACA (On/Off, 2–3 position) and NACM (modulating 0–10 V). 230 V or 24 V, run time 60–180 s, made in Switzerland, 24-month warranty.
  • RSKI – guillotine dampers, manual or with an electric actuator, for ventilation and dust extraction systems with sawdust or EPS particles. Withdrawing the damper opens the full passage. Tightness class F according to EN 12237.

Check valves for ducts

AVGI – check valves Ø100–315 mm for blocking reverse air flow. They are inserted inside the duct, no need to cut the duct.

How to choose a duct damper

SeriesDuct diameterPurpose
RSKØ100, 125 mmvolume control
RSKGØ100–400 mmmanual control, rubber seals
RSKHØ100–315 mmairtight shut-off, class 4 to EN 1751
RSK HDPEØ75, 90 mmfor HDPE ducts
RSKSØ80–315 mmvolume control and noise reduction
SEPGØ100–315 mmmotorised damper with actuator
RSKIØ100–400 mmguillotine damper for dust extraction, class F to EN 12237
AVGIØ100–315 mmback-draft prevention
Frequently asked questions
Which ventilation dampers suit air flow control?
For manual control – RSK, RSKG or RSK HDPE, for control and noise reduction – polyurethane RSKS.
What is the difference between control and shut-off dampers?
Control dampers (RSK, RSKG) change the air volume, RSKH shut-off dampers close the duct tightly (tightness class 4 according to EN 1751).
Which duct dampers should I choose for round ducts?
By duct diameter: RSKG – Ø100–400 mm, RSKH and SEPG – Ø100–315 mm, RSKS – Ø80–315 mm, RSK – Ø100 and 125 mm.
Are there automatic air flow dampers?
Yes, SEPG dampers with a NENUTEC electric actuator (NACA On/Off or NACM with 0–10 V control).
Which air dampers to use for HDPE ducts?
RSK HDPE for Ø75 and 90 mm HDPE ducts. RSKG75 is kept in stock.
What is special about RSKS polyurethane dampers?
They control air flow and reduce noise. They are installed in the end branch of the duct and the flow is set by increasing the number of open holes.
Which dampers suit dust or sawdust extraction systems?
RSKI guillotine dampers: withdrawing opens the full passage, tightness class F (EN 12237), manual or with an actuator.
What torque and control do NENUTEC actuators have?
2–40 Nm, On/Off (NACA) or 0–10 V (NACM), supply 230 V or 24 V, run time 60–180 s.
Are there dampers for blocking reverse air flow?
Yes, AVGI check valves (Ø100–315 mm) are inserted inside the duct.
Do you deliver ventilation dampers abroad?
Yes, we deliver worldwide.