Catalog
Catalogue
SEARCH
    • Price:

SEARCH

bulviukose.lt - recipes, salts, mustard, vinegar, syrups, oils

Items on Sale

Tvarkykime atliekas atsakingai

Galvanised steel ducts for heat recovery systems

Galvanised steel ducts for heat recovery systems form a sturdy main air line from the unit: ducts Ø80–500 mm, bends, branches, couplings, dampers and non-return valves.

We deliver worldwide. Read on at the bottom of the page.

From 5.75 €
11.48 €
Galvanized spiro duct SKO Ø80-200 mm
Save - 50 % Save - 50 %
From 37.13 €
74.28 €
Galvanized spiro duct SKO Ø250-500 mm
Save - 50 % Save - 50 %
From 14.56 €
19.41 €
45° duct adapters PAG45
Save - 25 % Save - 25 %
From 2.52 €
3.15 €
Duct adapters PA
Save - 20 % Save - 20 %
From 3.21 €
4.92 €
Duct adapters PAG
Save - 35 % Save - 35 %
From 1.56 €
2.34 €
Duct clamps, hangers OL
Save - 33 % Save - 33 %
From 26.57 €
35.42 €
Air damper for electric drive SEPG
Save - 25 % Save - 25 %
From 9.58 €
13.69 €
Air dampers RSK
Save - 30 % Save - 30 %
From 9.69 €
17.62 €
Air dampers RSKG
Save - 45 % Save - 45 %
From 16.17 €
29.40 €
Airtight dampers for ductwork RSKH
Save - 45 % Save - 45 %
From 1.77 €
2.35 €
Duct connectors MO
Save - 25 % Save - 25 %
From 1.78 €
3.56 €
Duct connectors MOG
Save - 50 % Save - 50 %
From 1.48 €
1.97 €
External duct connectors MOI
Save - 25 % Save - 25 %
From 6.97 €
11.60 €
Flexible duct connectors MOL
Save - 40 % Save - 40 %
From 3.42 €
6.85 €
Duct elbows with gaskets
Save - 50 % Save - 50 %
From 5.05 €
7.21 €
Duct elbows without gaskets
Save - 30 % Save - 30 %
From 101.28 €
135.04 €
Guillotine dampers RSKI
Save - 25 % Save - 25 %
From 26.37 €
35.15 €
45° pipe saddle taps BAG45
Save - 25 % Save - 25 %
From 3.69 €
6.16 €
Backflow valves AV, without gaskets
Save - 40 % Save - 40 %
From 19.93 €
26.56 €
Backflow valves to mount inside the duct AVGI
Save - 25 % Save - 25 %
From 16.99 €
21.25 €
Duct bends shortened 90°
Save - 20 % Save - 20 %
From 21.05 €
26.33 €
Duct bends shortened male-female 90°
Save - 20 % Save - 20 %
From 13.52 €
24.58 €
Asymmetric reducers for ducts ARG
Save - 45 % Save - 45 %
From 2.70 €
4.91 €
Pipe saddle taps BAG
Save - 45 % Save - 45 %

How to choose galvanised ducts for a heat recovery system

Galvanised steel suits main runs: the ducts are rigid, airtight and long-lasting. First set the diameter from the unit connection and airflow, then list the parts.

Ducts and fittings

SKO ducts Ø80–200 mm and SKO Ø250–500 mm come in sections from 0.5 to 3 m, standard lengths 1.5 and 3 m. Direction changes use bends without gaskets and with gaskets, and short 90° bends (Ø100–315 mm). Branches use flat branches PA, PAG and BAG, and asymmetric transitions ARG join different diameters.

Couplings and noise control

Ducts join with MO couplings, MOG with rubber gaskets and external MOI. At the unit, flexible couplings MOL (Ø100–315 mm) of galvanised steel and AMT material absorb vibration and cut noise.

Dampers and non-return valves

RSK and RSKG dampers balance airflow in branches, RSKH dampers meet tightness class 4 under EN 1751, and SEPG work with an electric actuator. AV and AVGI non-return valves block backflow.

PartDiametersPurpose
SKOØ80–500 mmstraight ducts
MOGØ80–500 mmcouplings with gaskets
MOLØ100–315 mmflexible couplings, vibration damping
RSKHØ100–315 mmshut-off dampers, class 4
AVØ100–400 mmnon-return valves

The REC in line and REC vertical units use Ø125 mm. For lighter runs see HDPE and flexible ducts, and for insulated versions EPP ducts.

Worldwide delivery of galvanised ducts for heat recovery

el-vent.com offers galvanised steel ducts for heat recovery, fittings and dampers. We deliver worldwide. If you are unsure about the system layout, write to us under Contacts and we will help you choose.

Frequently asked questions
Which galvanised duct diameters suit a heat recovery unit?

SKO come in Ø80–500 mm. The REC in line and REC vertical units use Ø125 mm, so start the main run at that diameter.

What is the difference between MO, MOG and MOI couplings?

MO joins Ø80–160 mm ducts, MOG has rubber gaskets (Ø80–500 mm) and MOI fits over the outside (Ø80–400 mm).

What are MOL flexible couplings for?

MOL of galvanised steel and AMT material absorb vibration and cut noise where a duct meets a unit or fan.

How do I balance airflow in branches?

Use RSK or RSKG dampers; RSKH meet tightness class 4 under EN 1751 and SEPG take an electric actuator.

Do I need a non-return valve?

AV and AVGI block backflow in the duct; they install inside the duct (AVGI Ø100–315 mm, AV up to Ø400 mm).