Price:
European delivery - 30 working days, other countries +7 working days.
Ask a question about this item
Ask a question about this item
DZD ATEX DUST – explosion-proof axial roof fans for explosive dust atmospheres, ≤6510 m³/h
DZD Ex t series axial roof fans with horizontal air discharge are designed for potentially explosive atmospheres containing combustible dust. The fans are intended for dust hazardous areas classified as Zones 21 and 22, subject to the certification and marking of the specific model.
The fans are designed for combustible dust atmospheres of Groups IIIA and IIIB. The series covers nominal sizes from 250 to 600 mm, with a maximum airflow of 6510 m³/h.
DZD ATEX DUST – manufacturer's technical catalogue (PDF)
Dimensions are given in millimetres (mm), weight in kilograms (kg).
| Model | A | ØB | C | ØD | ØE | F | ØG | ØH | I | kg |
| DZD Ex t 250 | 500 | 570 | 285 | 355 | 560 | 170 | 263 | 286 | 7 | 14 |
| DZD Ex t 300 | 570 | 660 | 335 | 405 | 630 | 190 | 313 | 356 | 9 | 20 |
| DZD Ex t 355 | 610 | 720 | 340 | 455 | 670 | 190 | 363 | 395 | 9 | 24 |
| DZD Ex t 400 | 650 | 830 | 375 | 505 | 710 | 190 | 413 | 438 | 9 | 27 |
| DZD Ex t 500 | 800 | 940 | 380 | 605 | 860 | 190 | 513 | 541 | 9 | 39 |
| DZD Ex t 600 | 840 | 1100 | 420 | 720 | 900 | 190 | 613 | 674 | 11 | 43 |

| Parameter | Value |
| Fan type | Axial roof fan |
| Air discharge direction | Horizontal |
| Application | Combustible dust atmospheres |
| ATEX category | II 2D |
| Hazardous area classification | Zones 21 and 22, subject to model certification |
| Dust groups | IIIA, IIIB, subject to certified marking |
| Nominal size | 250–600 mm |
| Maximum airflow | 6510 m³/h |
| Motor | Three-phase asynchronous |
| Motor temperature monitoring | PTC thermistors |
| Degree of protection | IP64 |
| Connection cable | 1.7 m |
| Housing material | Galvanised sheet steel |
| Installation location | Building roof |
The fans are designed for combustible dust atmospheres whose classification and operating conditions comply with the ATEX marking of the specific equipment. The manufacturer indicates a clean-air temperature range of −20 °C to +60 °C. The permissible conditions and surface temperature marking of each model must be checked against its documentation.
DZD ATEX DUST – technical specifications, performance curves, dimensions and accessories (PDF)
DZD Ex t fans are installed on building roofs with horizontal air discharge. They can be used for direct air extraction or in systems connected to ductwork.
The fan mounting base must be selected according to the roof structure, fan size and manufacturer's mounting dimensions.
The fans are equipped with three-phase asynchronous motors incorporating PTC thermistors in their windings. The motor is connected via a 1.7 m cable and a pre-wired explosion-protected terminal box.
The PTC thermistors must be connected to an appropriate motor temperature monitoring device in accordance with the manufacturer's instructions. MVS6 and TMS protection devices are available.
DZD ATEX DUST – manufacturer's technical catalogue and installation information (PDF)