Price:
European delivery - 30 working days, other countries +7 working days.
Ask a question about this item
Ask a question about this item
Fans for electrical cabinets RCQ 160.15 150x150 mm, 120 m³/h
RCQ 160.15 – axial fans for cooling electrical and server cabinets, 150×150 mm, 120 m³/h.
In the standard version the fan with filter is fitted at the bottom of the cabinet and supplies filtered cool air, while warm air leaves through the grille at the top. In the E version the extract fan is at the top and the filter grille at the bottom.
The fan is inserted into the cabinet wall cut-out and fixed with elastic clips or the supplied screws.
Data for all models are given in the technical information tab.
| Code |
A
|
B
|
C
|
D
|
E
|
| RCQ 160.15 | 148 | 148 | 5 | 68 | 120 |

Drilling scheme for fan and grille assembly
| Code |
A
|
B
|
Ø C
|
| RCQ 160.15 | 125 x 125 | 131 x 131 | 4.5 |
|
Code
|
Voltage, V
|
Frequency, Hz
|
Capacity, m3/h
|
Power, W | Current, A | Noise level, dB(A)3m | Weight, kg | |
| with filter IP54/IP55 | without filter IP54/IP55 | |||||||
| RCQ 160.15 ir RCQ 160.15 E | ||||||||
| IP54 12V dc | 12 | - | 55 / 51 | 120 / 120 | 5 | 0.4 | 37 | 0.5 |
| IP54 24V dc | 24 | - | 55 / 51 | 120 / 120 | 5 | 0.2 | 37 | 0.5 |
| IP54 12V ac | 12 | 50/60 | 60 / 56 | 110 / 110 | 17 | 2 | 40 | 0.75 |
| IP54 24V ac | 24 | 50/60 | 60 / 56 | 110 / 110 | 15 | 1 | 40 | 0.75 |
| IP54 48V ac | 48 | 50/60 | 60 / 56 | 110 / 110 | 16 | 0.5 | 40 | 0.75 |
| IP54 110-120V ac | 110-120 | 50/60 | 60 / 56 | 110 / 110 | 20 | 0.25 | 40 | 0.75 |
| IP54 220-240V ac | 220-240 | 50/60 | 60 / 56 | 110 / 110 | 20 | 0.125 | 40 | 0.75 |
| RCQ UL 160.15 ir RCQ 160.15 E-UL | ||||||||
| IP55 12V dc | 12 | - | 55 / 51 | 120 / 120 | 5 | 0.4 | 37 | 0.5 |
| IP55 24V dc | 24 | - | 55 / 51 | 120 / 120 | 5 | 0.2 | 37 | 0.5 |
| IP55 12V ac | 12 | 50/60 | 60 / 56 | 110 / 110 | 17 | 2 | 40 | 0.75 |
| IP55 24V ac | 24 | 50/60 | 60 / 56 | 110 / 110 | 15 | 1 | 40 | 0.75 |
| IP55 48V ac | 48 | 50/60 | 60 / 56 | 110 / 110 | 16 | 0.5 | 40 | 0.75 |
| IP55 110-120V ac | 110-120 | 50/60 | 60 / 56 | 110 / 110 | 20 | 0.25 | 40 | 0.75 |
| IP55 220-240V ac | 220-240 | 50/60 | 60 / 56 | 110 / 110 | 20 | 0.125 | 40 | 0.75 |
Pressure loss diagram


You might also like: