Price:
Galvanised steel ducts are the standard choice for ventilation in industrial, commercial and residential buildings. Here you will find SKO ducts Ø80–500 mm, bends, branches, transitions, couplings, dampers, non-return valves, hangers and aluminium tapes for sealing joints.
SKO ducts come in Ø80–200 and Ø250–500 mm, and the airflow in the run can be adjusted or fully shut off with RSK, RSKG, RSKH, guillotine RSKI or motorised SEPG dampers. Joints are sealed with gasketed couplings, and the ducts are fixed with OL hangers.
We deliver worldwide. Read on at the bottom of the page.
When planning a duct run, first determine the diameter from the airflow and the fan spigot, then compile a list of parts: straight ducts, bends, branches, couplings and fixings. All parts are made of galvanised steel, so they fit together and last long.
Galvanised steel ducts SKO Ø80–200 mm and SKO Ø250–500 mm come in sections from 0.5 to 3 m, with standard lengths of 1.5 and 3.0 m. The ducts are made of galvanised sheet steel with a length tolerance of ±1%.
Direction changes use bends without gaskets and bends with gaskets (Ø80–500 mm) as well as shortened 90° bends (Ø100–315 mm). For branches there are flat branches PA (Ø100–315 mm), PAG (Ø80–500 mm), 45° PAG45, saddle branches BAG and 45° BAG45 (Ø100–400 mm). Ducts of different diameters are joined by asymmetric transitions ARG.
Duct couplings MO (Ø80–160 mm) join ducts, couplings MOG (Ø80–500 mm) have rubber gaskets, and external couplings MOI (Ø80–400 mm) fit over the outside of the duct. Equipment is connected to the duct system by flexible couplings MOL (Ø100–315 mm): they are made of galvanised steel and the special material AMT, absorb vibration and reduce noise.
Airflow is regulated manually by dampers RSK (Ø100–125 mm) and RSKG (Ø100–400 mm). Shut-off dampers RSKH (Ø100–315 mm) with couplings and rubber gaskets meet tightness class 4 under EN 1751, while guillotine dampers RSKI close the flow. Dampers SEPG (Ø100–315 mm) work with an electric actuator. Backflow is blocked by non-return valves AV (Ø100–400 mm) and AVGI, which are inserted into the duct (Ø100–315 mm).
| Part | Diameters | Purpose |
|---|---|---|
| SKO | Ø80–500 mm | straight ducts |
| MOG | Ø80–500 mm | couplings with gaskets |
| MOL | Ø100–315 mm | flexible couplings, reduce noise |
| RSKG | Ø100–400 mm | manual regulating damper |
| RSKH | Ø100–315 mm | shut-off, tightness class 4 |
| AV | Ø100–400 mm | non-return valve |
Ducts are hung with hangers OL, which consist of two parts fastened with screws. The OLG model has EPDM gaskets that further reduce vibration and noise. Seal joints with aluminium tapes AS256, AS251, AS252, AS291, and in damp places with fabric tapes AS218 or AS215. For lighter runs there are flexible ducts and plastic ducts, and where the duct needs thermal insulation see insulated ducts.
el-vent.com offers galvanised steel ducts, fittings, dampers and hangers for ventilation systems. We deliver worldwide. If you are unsure about the diameter or the parts list, write to us under Contacts and we will help you draw up the specification.
SKO Ø80–200 mm and SKO Ø250–500 mm come in sections from 0.5 to 3 m, with standard lengths of 1.5 and 3.0 m. Bends, branches and couplings of the same diameters match them.
Ducts are joined with couplings MO or MOG with rubber gaskets, and MOI slide over the outside. Aluminium tape such as AS256 applied over the joint adds further tightness.
Hang ducts with hangers OL; the OLG model has EPDM gaskets that reduce vibration. Separate the fan or equipment from the duct with a flexible coupling MOL so vibration does not travel through the system.