Silent bathroom exhaust fans with EC motors ELEGANCE EC 2V

  • ELEGANCE EC 2V - silent bathroom exhaust fans with backdraft stopper and EC motors for direct extraction of air from kitchens, baths and other very humid areas
  • super economical two-speed EC motors with ball bearings
  • the fan runs continuously at low speed (one of the two low speeds can be set at the time of fan installation)
  • the axial impeller blows high volumes of air through Ø100 mm ducts and duct systems up to 3 m long
  • suitable for ceiling or wall mounting
  • models (all available in both 12 V, i.e. SELV models, and 230 V):

- SELV - 12 V motor (12 V transformer 2TR2041 included with any ELEGANCE SELV model)

- EC 2V - the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), switching on the switch activates the maximum speed, switching off the switch allows the fan to continue running at low speed
- EC 2V DT - with timer: the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), when the switch is turned on the maximum speed is activated and when turned off the fan will run for the time period set by the timer (from 2 minutes up to 30 minutes) and then fan switches back to the minimum speed. To avoid additional noises during the night, there is a possibility to delay the fan at maximum speed for 2 minutes during the night, i.e. if you are in the WC for less than 2 minutes the fan will not start at maximum speed, if you are in the WC for more than 2 minutes the fan will start at maximum speed and will operate for the time period set by the timer and then will switch back to the minimum speed.
- EC 2V HDT - with timer and humidity sensor: the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), when the switch is turned on it will run at maximum speed, and when turned off it will run for the time period set by the timer (2 to 30 min.) and then fan switches back to minimum speed. If the humidity level rises above the set point (control range from 40% to 90%), the fan will automatically switches itself to maximum speed and operate for a timer-set period of time. If the humidity level drops below the set point then the fan will switch to minimum speed, if the humidity level remains above the set point the fan will run at maximum speed for one more cycle. The number of cycles is unlimited until the humidity level falls below the set point. To avoid additional noises during the night, it is possible to delay the fan's maximum speed for 2 minutes during the night, i.e. if you are in the WC for less than 2 minutes, the fan will not run at maximum speed, if you are in the WC for more than 2 minutes, the fan will run at maximum speed for the time set by the timer and then switch back to minimum speed.

  • maximum ambient temperature 40 °C
  • complies with ErP Directive 2009/125/EC and EU Regulation 1253/2014
  • 5 years warranty
  • installation examples:

 

 
 
Air is drawn in from all sides by means of a cover

Brand: ELICENT
Code A ØB C D
ELEGANCE 100 EC 2V 160 98 80 38

 

Code Motor m³/h l/s Pa W dB(A)* kg
ELEGANCE 100 EC 2V EC 97 / 49 / 30 27 / 14 / 8 34 / 10 / 4 3.5 / 0.8 / 0.5 32 / 16 / 15 0.9
ELEGANCE 100 EC 2V DT EC 97 / 49 / 30 27 / 14 / 8 34 / 10 / 4 3.5 / 0.8 / 0.5 32 / 16 / 15 0.9
ELEGANCE 100 EC 2V HDT EC 97 / 49 / 30 27 / 14 / 8 34 / 10 / 4 3.5 / 0.8 / 0.5 32 / 16 / 15 0.9
ELEGANCE 100 EC 2V 12V EC 81 / 49 / 30 22.5 / 14 / 8 24 / 10 / 4 2 / 0.8 / 0.5 32 / 16 / 15 0.9
ELEGANCE 100 EC 2V DT 12V EC 81 / 49 / 30 22.5 / 14 / 8 24 / 10 / 4 2 / 0.8 / 0.5 32 / 16 / 15 0.9
ELEGANCE 100 EC 2V HDT 12V EC 81 / 49 / 30 22.5 / 14 / 8 24 / 10 / 4 2 / 0.8 / 0.5 32 / 16 / 15 0.9

*LpA, measured at 3 m in open field 230V-50 Hz

 