Explosion proof axial duct fans AVWOKE EX ≤1200 m³/h
Explosion proof axial duct fans AVWOKE EX ≤1200 m³/h

European delivery - 30 days, other countries +7 days.

Ask a question about this item

Ask a question about this item

Explosion proof axial duct fans AVWOKE EX ≤12000 m³/h

  • AVWOKE EX - Ø315-560 mm explosion-proof axial duct fans designed to convey vapor or gas directly outside from commercial, industrial and other premises where there is a high risk of explosion due to explosive or flammable gas
  • complies with ATEX directive
  • AVWOKE 2G - fans intended for operation in Z1 (1) and Z2 (2) gas explosion zones are identified by the following symbols:
  • temperature class: T1 to T3 (special order T4)
  • explosion group: II (Subgroups IIA and IIB)
  • fans not fitted for speed control
  • maximum ambient temperature 40 °C
  • AVWOKE 3G / 3D - fans designed to operate in the Z2 (2) and Z22 (22) gas and dust explosion areas are identified by the following symbols:
  •  

  • temperature class: T1 to T3
  • maximum dust surface temperature up to 120 °C
  • maximum ambient temperature 40 °C
  • gas explosion group: IIA and IIB
  • dust explosion group: IIIB
  • fans adapted for speed control by a special frequency converter
  • temperature sensors (3xPTC 155C) mounted on the fan motor should be connected to an EC certified relay to ensure proper motor protection during control
  • explosion-proof fans for zone Z1 (1) with frequency converter can be ordered on request
  • the reverse is available on request for all models
  • fan housing made of galvanized steel, powder or antistatic coated (depending on model)
  • axial impeller made of special antistatic material
  • all models with three-phase, explosion-proof electric motors
  • motor side hot galvanized or powder coated, impeller side mesh available on request
  • manufactured under Directive 8/37/EC - Machinery Safety, Directive 94/9/EC (ATEX) - Equipment and protective systems in potentially explosive atmospheres
  • marking of zones:
  • Z1 - zone in which, under normal conditions of use, a vapor or gas mixture may be formed
  • Z2 - zone with low probability of explosive gas mixture, explosive mixture may only be present for a short time
  • Z22 - area with low probability of formation of explosive dust mixture, ie. transient, for example, during a fault
  • 1 year warranty

Brand: ESEM
Code
AVWOKE EX
Ø D
Ø D2 L
nxØd
31 315 352 350 8x9.5
35 355 392 350 8x9.5
40 400 438 440 8x9.5
45 450 488 440 8x9.5
50 500 538 450 8x9.5
56 560 600 450 12x9.5

 

 

Code
AVWOKE EX
Phase
Voltage, V at 50 Hz
Capacity, m³/h
Pressure, Pa
Power, W Noise level, dB(A)4m Speed, min-1 Current, A Weight, kg
31 III 400 2808 79 250 56 1400 0.8 16
35 III 400 4530 82 250 60 1400 0.8 18
40M III 400 3890 29 180 52 900 0.8 22
40D III 400 6084 95 250 62 1400 0.8 22
45M III 400 4700 38 182 54 900 0.8 23
45D III 400 7350 100 370 65 1400 1.3 24
50M III 400 6120 43 180 55 900 0.8 27
50D III 400 9900 105 550 65 1400 1.6 28
56M III 400 7040 53 370 59 900 1.3 34
56S III 400 11000 130 550 63 1400 1.6 34
56D III 400 12000 158 1100 79 1400 2.7 45

 